HT

HT TefloGas Filter Cartridges

Hydrophobic PTFE Membrane  ·  Sterile-Grade Filter for Critical Gas Filtration

HT TefloGas Filter Cartridges are composed of a PTFE membrane with advanced high-temperature-resistant core and internal adaptor. They are specially designed for air, gas, and vent sterile filtration at critically high temperatures.

Features and Benefits of HT TefloGas Filter Cartridges

  • Designed for Water Intrusion Test (requires no alcohol)
  • Oxidation-resistant materials provides longer service life in high temperature air and vent applications
  • Exceptionally high flow rates with low pressure drops
  • Part/Serial numbers are laser-etched and have 2D matrix code for easy tracking
  • Filter construction provides steam resistance at high temperatures

Quality Standards

  • Integrity Test correlates to ASTM F838-05 Bacterial Challenge Test (BCT)
  • Each filter is individually Integrity Tested prior to leaving the factory
  • Each filter is Fully Traceable with a unique serial number
  • Designed, developed and manufactured in compliance with ISO9001
  • Full Regulatory Compliance with the following:
    • 21CFR.210.3(b)(5)(6), 211.72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ml/10inch filter
    • USP <88> Plastic Class VI-121°C
    • FDA 21 CFR177-182 & EU 1935/2004/EC

Typical Applications of HT TefloGas Filter Cartridges

  • Autoclaves
  • Fermented Inlet Air
  • Aseptic Packaging/Blow-fill Seal (BFS)
  • Hot Water for Injection (WFI) Tank Vents
  • Oxygen-rich Fermented Air

Flow Rate Characteristics – HT TefloGas Filter Cartridges

Materials of Construction – Hall Pyke HT TefloGas Filter Cartridges

Filter Media Hydrophobic PTFE Membrane
Support/Drainage Layers Polyphenylenesulphide (PPS)
Core/Cage/Endcaps Polypropylene

Operating Conditions

Max. Temperature 100°C
Max. Differential Pressure 5.4bar/50°C(forward)
4.1bar/80°C(forward)
Effective Filtration Area 0.68m2 / Ω 68-10 inch

Sterilisation

In-line Steam Sterilization up to 100 forward cycles (145°C for 30min at 30kPa for every cycle)
Autoclave up to 400 cycles (130°C for 30min per cycle)

Integrity Test Data

Bubble Point BP : ≥0.11Mpa (60%/40%IPA/Water), 0.01μm
Diffusion Flow DF : ≤16ml/min/10”cartridge@80KPa(60%/40%IPA/Water), 0.01μm
Water Intrusion Test WFT : ≤0.53ml/min/10”cartridge@0.25MPa,0.01μm

Ordering Information

Removal Ratings End Cap Nominal Length Seal Material
0001=0.01 _m HSF=226 /Fin (PBT Insert) 10=10″ S=Silicone
0022=0.22 _m HSC=226 /Flat (PBT Insert) 20=20″ E=EPDM
HTF=222 /Fin (PBT Insert) 30=30″ V=Viton
HTC=222 /Flat (PBT Insert) 40=40″ P=FEP Encapsulated Viton
DOE=Double Open End K=PTFE

Downloads

File Description File size Downloads
pdf Hall Pyke HT 1 MB 838