Hall Pyke Capsules

Hall Pyke capsules are designed and manufactured by Critical Process for small flow and encapsulated disposable cartridge requirements. CP capsules are offered in a wide range of pleated and depth medias and offered in four grades; general, food / beverage, electronic and pharmaceutical. Each Capsule has been designed to hold the maximum amount of filter media that can be completely and effectively utilized in a capsule. CP capsules lower the cost of filtration and reduce the need for high cost metallic housings. They are well suited for liquids and gas applications with the same attention to quality, traceability, validation and testing.

Construction Materials

Housing: Polypropylene
Filtration Media: Membranes
Polyethersulfone
Nylon
Polypropylene
PTFE
Depth Pleated
Polypropylene
Fiberglass

All materials of construction are FDA accepted. Final assemblies have been validated to pass USP class 6 Toxicology extractable tests, oxidizable substances for plastics, endotoxin level and other quality

Sanitization / Sterilization

Filtered Hot Water: 1940F (90°C)
Autoclave: 2600F (127°C), 30 min, multiple cycles

Chemical Sanitization

Industry standard concentrations of hydrogen peroxide, paracetic acid, sodium hypochlorite and other selected chemicals. Sanitization protocols designed to extend the useful life of CP capsules are available from Critical Process Filtration, Inc.®.

Pre Sterilized

CP capsules are offered in both a non and pre sterilized grade.

Filtration Media Support: Polypropylene
Support Components: Polypropylene
Sealing Method: Heat – Fused

Downloads

File Description File size Downloads
pdf Hall_Pyke_Capsules 377 KB 961

Product Attributes

Inlet & Outlet Options

  • 1/4” Female NPT
  • 1/4” Male NPT
  • 3/8” Female NPT
  • 1/2” Female NPT
  • 1/2” Male NPT
  • Sanitary
  • Hose Barb.

Vent & Drain

Standard with LuerLok® ports and caps.

Maximum Operating Parameters

Liquid Operational Pressure: 80 psi (5.5 bar) at 20°C.
Gases Operational Pressure: 60 psi (4.1 bar) at 20°C.
Forward Differential Pressure: 50 psi (3.4 bar) at 20°C.
Reverse Differential Pressure: 40 psi (2.7 bar) at 20°C.
Operating Temperature: 110°F (43°C) at ≤ 30 psi (1.4 bar) in water.
Recommended Change Out Pressure: 20 psid (2.4 bar)

Pore Size

Removal Ratings: 0.03 to 100 microns

Dimensions

Nominal Length: (length based on capsules with hose barb connections)
Capsule 2” 5” 10” 20” 30”
Inches 5” 8 5/8” 13 3/8” 22 7/8” 32 7/16”
cm 12.7 22.0 33.9 58.2 82.4
Surface Area
Feet 1.0ft2 3.0ft2 6.8ft2 on request on request
cm 930cm2 2788cm2 6318cm2 on request on request

Outside Diameter: 3.50 inches (8.9 cm) nominal.